Earlex 0HV6003PUS Instruction Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
TROUBLESHOOTING
PROBLEM CAUSE ACTION REQUIRED
Little or no spray Air inlet blocked Check the condition of the Air Filter (1)
and clean or replace
Check air inlets, air vents and air hose for
blockages
Turbine has no
power
No power at supply Check the power supply
Cable fuse has blown Where applicable check fuse and replace
if necessary
Circuit Breaker (3) has tripped Reset the Circuit Breaker (3)
Incorrect or damaged power cord
set used
Use correct power cord set. Replace if
necessary
Worn turbine brushes Replace brushes at an authorized
service centre